FEATURES

  • Supply:
    60÷240 Vac ±15% single-phase (single rotor)
    380÷460 Vac three-phase (single, double triple rotor) .
  • Frequency: 50/60Hz
  • Output power:
    900 W, with 7 A limit at 220V single-phase 3.000 W with 10 A limit at 380 V three-phase. Overload 20% of the set value during 30"
  • CAN BUS communication with supervisor unit up to 1 Mbaud
  • IN/OUT for master slave, tandem or big size brakes
  • External setpoint input
  • Cell input
  • Digital pick-up input
  • Analog pick-up input
  • Amplified pick-up output
  • Line Receiver encoder input
  • 4 optocoupled inputs for various alarms
  • 2 Relay outputs
  • Power section provided of a random inversion function on the coil polarity for degmanetization after every single switch - on or after a command of zero current delivery.
  • Short circuit or coil protection, coil opening, short circuit to ground
  • Brake coils balance control
    (for 380/460Vac only)

    Option power for triple rotor:
    1500 W - max 10 A to be connected in addition to the three-phase 380 V unit

 

MODEL:

MODEL A B C D
220Vac 246mm 211 mm 83mm 15mm
380Vac 305mm 255mm 113mm 15mm

SUPPLY UNIT FOR THE EXCITATION OF DYNAMOMETER BRAKES:

  • 60÷240 Vac single rotor
  • 380÷460 Vac single -double -triple rotor
  • CAMBUS communication with Supervisor unit (up to 1Mbaud)
  • Liquid coolinng

Itaco S.r.L. -Via Riviera Berica, 40-36024 Ponte di Nanto(VI)
 
 


©1984-2007 Itaco S.r.L.